< Previous | Contents | Next >

7.13 Troubleshooting ENF Problems


Table 1: Troubleshooting ENF Problems


Problem

Probable Cause

Fix

Notes and symbols appear as large letters.

Font association lost.

Reinstall Chopin10 font. Font is located in the SmartScore directory.

Measures outlined in a red color.

Incorrect rhythm in one or more voices.

Edit voicelines to agree with time signature.

Pickup or closeout mea- sure highlights red & doesn’t play smoothly.

Voiceline durations do not agree with the current time signature

With Properties tool selected, click on barline that begins the measure. Select “As written”.

Only one system high- lights black at a time.

View active staffline is ON (default selection).

Check off View Active Staffline in View menu.

Measure remains high- lighted but measure plays back smoothly.

Secondary voice may be truncated (not fully com- pleted in the measure).

This is a common con- vention in music notation. May be left as is.

Can’t delete an object when “X” key is pushed.

Actual object must be selected first.

“Ctrl + click” the object before deleting. Or, sim- ply use the Select tool (“O” key) & drag around an object then hit Delete.

New note is inserted when trying to change an existing note.

Existing note was not highlighted yellow when clicked.

Yellow-highlighted notes will be changed to new value. Blue inserts new note at same time slice.

Measures unexpectedly roll from one system to another.

Barlines at the end or beginning of measures may have been deleted.

Restore the number of measures per system by opening Staff Properties with Properties tool.

Systems unexpectedly roll from one page to another.

Line, staff or system spacing may have been changed.

Readjust spacing tabs in left margin until systems are restored to page.

Table 1: Troubleshooting ENF Problems


Problem

Probable Cause

Fix

Staffline missing from system

Staffline cut off or during scanning or was not localized during Recog- nition.

Restore missing staff. See Section 4.13.2

Wrong part suddenly plays.

Expanding / collapsing score; Part / instrument linking lost.

Reassign parts in system. See Section 4.14

Display shows notes as brightly colored or with green vertical lines or with a solid orange hori- zontal line along the staff line.

ENF display is in Hidden Objects, Tempo or Veloc- ity controller mode.

Exit Hidden mode. See


image

image

For Windows

9x I 2x I NT I ME I XP



c:::

J0J0.


:=1

8


'-'I

0

ENF Editor Quick Keys Map


Hold and drag note to change pitch


Cntl + Click = Quick-Select: ctrl 1 ""

'2

'2

0

1:12

3

::>::1

1:12

Clicked object becomes selected 1 1 I op110

for Insert and Change actions.


Cntl + Active System = Hold SINGLE I

(")


(1)

"'

-@!

Cntl maintains current system as

Active System while cursor

image

moves outside system.

CLUSTER

DELETE I


Barline (Insert/ Delete)

N g

=e-


With CNTc--'

E Error Che<k

ft - Paste I ReplcK:e

T - Transtme

I- New MIDIView

S - Instrument Templates

C·Colo Page l Part Linking 8-Bracketing

M - Master System

9 • Playb;KI< Console

I I

I I

DELETE ANY INSERT I CHANGE

Beam Direction Toggle


Stem Direction Toggle Dot (Insert I Delete)

Unify Key, Time, Clef


L----Join Selected Voices

L_ Split Voices


L-----Select Region to Beam Notes


'------- Select Region to Delete Ties

...._ Tie (Insert I Delete)

...._ Flag I Beam Toggle


image